MeV-scale internal calibration sources for large LXe detectors

26 Oct 2023, 16:56
7m
48/1-112C/D - Redwood C/D (SLAC)

48/1-112C/D - Redwood C/D

SLAC

2575 Sand Hill Rd Menlo Park, CA 94025
60
Lightning talk Session 1/1

Speaker

Brian Lenardo (SLAC)

Description

By design, large-scale liquid xenon TPCs enjoy powerful self-shielding; gamma rays that would create backgrounds are strongly attenuated by the liquid at the edges of the detector. This, however, presents a challenge for calibrations: calibration sources placed outside the detector will only rarely penetrate to the center of the TPC, making the most sensitive region of the experiment also the most difficult to characterize. Radioisotopes that can dissolve directly into liquid xenon can address this problem. While many such sources are already in use, they are generally either a) alpha sources, which have dramatically different light and charge response, b) continuous-spectrum beta sources, or c) they deposit energies far below the 0nuBB Q-value of 136Xe. I will discuss some possibilities for dissolvable radioisotopes that would provide O(MeV) gamma ray lines, which could be used for energy scale calibrations of large LXe detectors.